Sunday, 14 December 2014

EXPERIMENT: SEIVING

TITLE: Sieving

OBJECTIVE: To determine the size and size distribution of lactose and microcrystalline cellulose (MCC).

INTRODUCTION:          A test sieve is a measuring instrument which is used to measure the particle size. They are made with only the highest quality materials and are available in diameter sizes of 38, 100, 150, 200, 250, 300, 315, 350, 400 or 450 mm as well as in 3, 8, 12 or 18 inches.          The sizes of solid particles from 125mm down to 20 microns can be measured efficiently by standard test sieve. A test sieve can be performed on any type of non-organic or organic granular materials including sands, crushed rock, clays, granite, feldspars, coal, soil, a wide range of manufactured powders, grain and seeds.

       In this experiment, two excipients used in tablet formulations, namely lactose and microcrystalline cellulose (MCC) are given to measure its particle size and measure the size distribution by using the test sieve. The diameter size of test sieve we are using in the experiment are 50, 150, 200, 300 and 425mm.



APPARATUS:
Sieve nest, weighing boat, analytical balance 
Sieve nest 

CHEMICALS:
Lactose, microcrystalline crystal (MCC)

EXPERIMENTAL PROCEDURE:
  1. A 100g of Lactose powder was weighed. 
  2. The sieve nest was prepared in descending order where the top being the largest in diameter and the bottom being the smallest in diameter. 
  3. The powder was then placed at the uppermost sieve and allowed the sieving process to proceed for 10 minutes. 
     
  4. Upon completion, the powder that was collected at each sieve was weighed and a particle  size distribution was plotted in a histogram. 
  5. The process was repeated using Microcrystalline Cellulose(MCC).
RESULT :

Diameter of sieve (µm)
Range of size of lactose (µm)
Weight of lactose(g)
<50
0-50
3.7975
50
50-150
93.7331
150
150-200
1.4084
200
200-300
0.8361
300
300-425
0.0091
425
>425
0.0059
Total
99.7901

Graph of weight of lactose against size of lactose

Diameter of sieve (µm)
Range of size of microcrystalline cellulose, MCC (µm)
Weight of microcrystalline cellulose, MCC(g)
<50
0-50
  52.4928
50
50-150
40.4162
150
150-200
3.3123
200
200-300
1.8172
300
300-425
0.1300
425
>425
0.0823
Total
98.2508

Graph of MCC against MCC size  

QUESTIONS:

1. What are the average particle size for both lactose and MCC? 

Base on the result obtained, the average particle size for lactose is 100µm and the average particle size for MCC is 25µm.



2. What other methods can you use to determine the size of particles? 


Other methods to determine the size of particles are sedimentation, elutriation, using a Coulter counter and Dynamic light scattering. 
Sedimentation is the tendency for particles in suspension to settle out of the fluid in which they are entrained, and come to rest against a barrier. This is due to their motion through the fluid in response to the forces acting on them(gravity, centrifugal acceleration or electromagnetism). Settling is the falling of suspended particles through the liquid, whereas sedimentation is the termination of the settling process. Sedimentation may pertain to objects of various sizes, ranging from large rocks in flowing water to suspensions of dust and pollen particles to cellular suspensions to solutions of single molecules such as proteins and peptides. Even small molecules are able to supply a sufficiently strong force to produce significant sedimentation. The term is typically used in geology, to describe the deposition of sediment which results in the formation of sedimentary rock, and in various chemical and environmental fields to describe the motions of often-smaller particles and molecules. Process is also used in biotech industry to separate out cells from the culture media. 
Elutriation is a process for separating particles based on their size, shape and density, using a stream of gas or liquid flowing in a direction usually opposite to the direction of sedimentation. This method is mainly used for particles smaller than 1 μm. The smaller or lighter particles rise to the top (overflow) because their terminal sedimentation velocities are lower than the velocity of the rising fluid. The terminal velocities of any particle in any medium can be calculated using Stokes' Law. 
A Coulter counter is an apparatus for counting and sizing particles suspended in electrolytes. It is used for cells, bacteria, prokaryotic cells and virus particles. A typical Coulter counter has one or more micro-channels that separate two chambers containing electrolyte solutions. As fluid containing particles or cells is drawn through each micro-channel, each particle causes a brief change to the electrical resistance of the liquid. The counter detects these changes in electrical resistance. 
Coulter counter

Dynamic light scattering, also known as photon correlation spectroscopy or quasi-elastic light scattering, is a technique in physics that can be used to determine the size distribution profile of small particles in suspension or polymers in solution.  It can also be used to probe the behavior of complex fluids such as concentrated polymer solutions.

Dynamic Light Scattering

3.What are the importance of particle size in pharmaceutical formulation?

The particle size distribution of active ingredients is an important physical characteristic of the materials used to create pharmaceutical products. The size, distribution and shape of the particles can affect the rate of reactions, potential to dissolve, packing density, sedimentation, effectiveness of drug delivery(inhalation), product appearance and texture. The link between particle size and product performance is well documented with regards to dissolution, absorption rates and content uniformity. Reducing particle size can aid the formulation of NCE’s with poor water solubility. Proper matching of active ingredient and particle size is important.

a) Rate of reactions
When it comes to solids, the surface area of the particle is critical in determining the rate of chemical reaction. Chemical reactions are far more likely to occur in fine particles than otherwise. A great example of an industry reliant on this principle is the cement industry, which must deliver the appropriate reaction rate in order to achieve the desired product.

b) Potential to dissolve
The effect of particle size on dissolution rate is similar to the influence of particle size on the reaction rate. By creating finer particles and therefore increasing surface area, the physical barriers to dissolution are weakened, making the process occur much more quickly. Put simply, finer particles are more likely to dissolve quicker. The pharmaceutical industry knows the importance of this, as the speed of dissolution has direct effects on bioavailability and, therefore, the effectiveness of any given drug.

c) Packing density
The efficiency with which particles pack together is crucial to many industries as well. As a rule, large particles are going to pack more poorly than small particles. By decreasing the particle size, packing density is improved and voidage (unoccupied volume) is reduced. This is particularly important in production of metals through mould filling, as unoccupied volume can create a significantly flawed product.

d) Sedimentation
Suspension “stability” is most easily achieved buy avoidance of sedimentation (ie. the tendency of particles in suspension to settle out of the fluid). In order to ensure stability, the gravitational pull exerted on particles must be balanced with the “up-thrust” of the fluid. Unstable suspensions can wreak havoc in the food industry, for example, where consistency is essential to product perception.

e) Effectiveness of drug delivery by Inhalation
In order to maintain the integrity of air supply in the body, our respiratory systems are incredibly efficient at filtering out particles above a certain size. This stops these particles from entering and damaging the lungs. Orally or nasally inhaled drug manufacturers must ensure the product is capable of penetrating the lungs; conversely, cleaning product manufacturers may need to provide extra controls in order to prevent inhalation if particles are of a dangerous size.

f) Product appearance
The principle behind the particle size analysis technique of laser diffraction is that particles will scatter light in different ways depending on their size. In some industries, however, this principle is important not just for analysis but also for end product — paint manufacturers, for example, must achieve desirable light scattering effects in order to define parameters such as hue, tint, transparency, gloss and so forth.

g) Texture
Overall, the size of particles can have direct correlation with a customer’s perception of a product and, therefore, the reputation of a manufacturing company. This is particularly true in the case of food products in which particle size can impact the enjoyment of the product; take coffee, for example, with which particle size affects the flavours released in the brewing process.

DISCUSSION :
          In this experiment, 100g of lactose and microcrystalline cellulose (MCC) powders are placed on the sieve nest and are sieved for 10 minutes using a sieve shakers and the particle size distribution of both powder are determined. There is a total of five sieve nests used and they ae arranged in a descending order of their diameter, which the sieve nest with largest diameter is placed on the top, whereas the sieve nest with the smallest diameter is placed on the bottom.
         When lactose is sieved, the lactose that obtained in the sieve with diameter of 300µm and 425µm are very less, which are 0.0091g and 0.0059 g respectively. This means that the size of lactose particle is finer. The lactose obtained in the sieve with diameter of 50µm is the most. This shows that the lactose mostly remain at size of 50-150µm. For microcrystalline cellulose, the weight of MCC of size 0-50µm and 50-150µm is the largest, which are 52.4928g and 40.4162g respectively. This means that the size of MCC is normally exist in the range of 0-150µm.
        The total of the weight of lactose and MCC obtained is not the same as their original weight due to some errors such as the effect of the surrounding air which cause some of the lactose and MCC to be blown off when they are transferred from the sieve to the weighing board. There are also some precaution steps that need to be taken during the experiment. Make sure that the sieve shaker is set up properly before starting the sieving process.

CONCLUSION :
       Sieve method can be used to determine the particle size and size distribution of a powder. The normal range of size of lactose is 50-150µm, whereas the normal range of size of microcrystalline cellulose (MCC) is 0-150µm.

Friday, 5 December 2014

EXPERIMENT: PARTICLE SIZE AND SHAPE ANALYSIS USING MICROSCOPE

TITLE: Particles Size and Shape Analysis Using Microscope

OBJECTIVE:
1)  To analyse and interpret the shape of particles with five different samples.
2)  To observe and compare the size of particles for each sample.

INTRODUCTION:
     The need for particle size control in the manufacture of pharmaceuticals is becoming increasingly apparent as the pharmaceutical industry attempts to capitalize on some APIs with less-than-ideal solubility profiles. Also, significant advances in drug delivery have been made in which a finely divided API, with the concomitant increase in specific surface area, has resulted in increased bio-availability. Precise particle size control technologies have also assisted in the development of drug delivery platforms for the delivery of a medicament to the lung. As these trends have occurred, the need for highly reproducible particle size assessment techniques has grown significantly in the past decade. The interest in particle size   measurements will remain high, particularly in view of FDA trends toward recommending more thorough descriptions of particle size distributions in submissions in which the emphasis of a drug product claim is based in a tightly controlled particle size. When drug is synthesized and formulated, the particle size of drug and other powder is determined and this influences the subsequent physical performance of the medicine and the pharmacological of the drug.
     Powder with different particle sizes have different flow and packaging properties, which alter the volumes of powder during each encapsulation or tablet compression event. The particles which are having small dimensions will tend to increase the rate of solution.
     In order to obtain equivalent diameters with which to analyse and interpret the particle size of powder, it is necessary to carry out a size analysis using different methods. One of the methods for particle analysis is using microscope. The use of a microscope to examine and measure particle is very effective procedure and it is the only method in which direct measurement of the particles is made.

MATERIALS AND APPARATUS:
Electron Microscope, weighing boat, five (5) different size of sand  (A=850 microns, B=500 microns, C=355 microns, D=150 microns, E=various), MCC powder, Lactose powder and prepared slide
Prepared slide
Electron Microscope

EXPERIMENTAL PROCEDURE:
  1. Microscope was set up.
  2. Five different particle samples were labelled with A, B, C, D and E.
  3. A pinch of sample A was taken and put on the slide. The particles were separated one with another to prevent from redundant particle on one place. This will prevent accurate analysis of size and shape of particles.
  4. The sample was put on the slide and observed the particles size and shape using microscope with magnification x10.
  5. The shape and size of particles had been drawn and analysed.
  6. The experiment was repeated by changing the particles and used sample B, C, D , E , MCC powder and lactose powder.

RESULTS
TYPES OF SANDS AND POWDERS
IMAGE
CHARACTERISTICS
Sand 150 microns




  • rough edges due to the presence of attached material
  • smallest size particle diameter
  • different size particles  which include smaller and larger particle size
  • shape cannot be indentified clearly

Sand 355 microns




  • rough edges due to the presence of attached material
  • smaller particle diameter compared to 500 microns sand
  • different size particles which include smaller and larger particle sizes
  • non- spherical shape



Sand 500 microns




  • rough edges due to the presence of attached material
  • larger diameter compared to 355 microns sand
  • different size particles
  • irregular shape



Sand 850 microns




  • defined edges and no attached material
  • larger particle diameter compared to 500 microns sand
  • same size particles
  • non- perfect spherical shape 
Various sand






  • rough edges due to the presence of attached material
  • largest particle diameter
  • different size particles
  • spherical and irregular shape
  • Lactose





    • presence of attached material
    • very fine particles
    • shape cannot be identified clearly
    • has projection
    Microcrystalline cellulose (MCC)



    • presence of attached material
    • particles size larger than lactose particles
    • shape cannot be identified clearly
    • has projection 


    QUESTIONS
    1.      Explain in brief the various statistical methods that you can use to measure the diameter of a particle.
    Many methods are available for determining particle size such as microscopy, sedimentation sieving, Coulter counter, adsorption, elutriation and laser spectrometer. Although the microscope allows the observer to view the actual particles, the results obtained are probably no more “direct” than those resulting from other methods because only two of three particle dimensions are ordinarily seen. The sedimentation methods yield a particle size relative to the rate at which particles settle through a suspending medium, a measurement important in the development of emulsions and suspensions. Sieving is the method that uses a series of standard sieves calibrated by the National Bureau of Standards. Sieves are made up of wire mesh with opening of known size. To determine particle size by this method, a nest of sieves with the coarsest on top is placed on the shaker and the powder sample placed on the top of sieve. Particle diameter is considered as the size of the opening in the larger or finer sieve or as the size of the arithmetic or geometric mean of the opening of the two sieves. The measurement of particle volume, using an apparatus called the Coulter counter, allows one to calculate an equivalent volume diameter. The Coulter Counter determines the particle volume distribution of materials suspended in an electrolyte- containing solution. This instrument utilizes an electrical sensing zone and measure electrical pulses caused by the passage of particles through the zones. Adsorption of a solute from solution or of a gas at low temperatures onto powdered material serves as a measure of the particle surface area that can determine its diameter. In elutriation, the particles are suspended in a moving fluid, generally water or air. In vertical elutriation at any particular velocity of the fluid, particles of a given size will move upwards with the fluid, while larger particles will settle out under influence of gravity. In horizontal elutriation, a stream of suspended particles is passed over a settling chamber. Particles that leave the stream are collected in the bottom of the chamber. Other methods of measuring particle diameter size include a laser diffraction. It is a common, and fully automated, in-line method of measuring the particle size distribution of a sample. The light-scattering effect caused by the interaction of a laser beam with particles is measured by an array of detectors. The size distribution of the particles can then be calculated using the principle that the angle of diffraction of the light is inversely proportional to the particle size. Every method has a suitable size range for measurement. Since the particle size measurements obtained by methods differing in principle will yield different results, it is necessary to be aware of and to understand the method and size characteristic involved in any particular method. For the measurement diameter of particle, therefore, one should select the method most suitable for the purpose of the measurement after considering the history of the powder sample and deciding upon the appropriate size characteristics.

    2.      State the best statistical method for each of the samples that you have analysed.
    Sedimentation is the best statistical method. The application of ultracentrifugation to the determination of the molecular weight of high polymers has already been discussed. The particle size in the subseive  range can be obtained by gravity sedimentation as expressed in Stoke’s law, The equation holds exactly only for spheres falling freely without hindrance and at a constant rate. The law is applicable to irregularly shaped particles of various sizes as long as one realizes that the diameter obtained is a relative particle size equivalent to that of sphere falling at the same velocity as that of the particles under consideration. The particles must not be aggregated or clumped together in the suspension because such clumps would fall more rapidly than the individual particles and erroneous results would be obtained. The proper deflocculating agent must be found for each sample that will keep the particles free and separate as they fall through the medium. There are two common sedimentation methods which are integral sedimentation and differential sedimentation. Integral sedimentation can be applied to particles lower in density than the fluid in which they are suspended. In this case, the particles have a net buoyancy, so they sediment toward the surface of the fluid rather toward the bottom. In differential sedimentation, a sample of particles to be analyzed is placed on top of column of clear liquid at the start of the analysis, and the particles settle according to Stoke’s Law, just as in integral sedimentation.

    DISCUSSION:
              In this experiment, five different types of sands and powders with particular emphasis on the size and shape of particles are analysed. For the analysis of particle size by using microscope, it is carried out on two-dimensional images of particle. It is normally assumed to be oriented randomly in three dimensions. This assumption is considered valid for most of the cases. 
    However for dendrites, fibres or flakes it is very unlikely that the particles will orient with their minimum dimensions in the plane of measurement. Therefore, the size analysis is carried out by assuming they are viewed in their most stable orientation. Thus, overestimation of size occurs as the largest dimensions of the particle will be observed as the smallest dimension will most often orientate vertically.
         The two dimensional images are analysed according to the desired equivalent diameter. Disadvantages of this method include it is not suitable for quality control, elaborate sample preparation and slow and rapid operator fatigue.


    CONCLUSION:
    In conclusion ,different types of particles (sand or powder) have different properties in terms shape,size and diameter. 

    REFERENCES:
    1) https://books.google.com.my/books?id=jayzqzefqUsC&pg=PA65&lpg=PA65&dq=size+and+particle+analysis+experiment&source=bl&ots=e25EbMF6Ul&sig=F4p8qDCk4nn6AukyK2WEi3PdJ3g&hl=en&sa=X&ei=3aCNVOPZAsfJuATGu4KgBw&sqi=2&ved=0CGcQ6AEwCA#v=onepage&q=size%20and%20particle%20analysis%20experiment&f=false
    2)  http://www.nature.com/nature/journal/v162/n4113/abs/162329b0.html